ANAESTHETIC MACHINE DIAMOND STANDARD

ANAESTHESIA MACHINE DIAMOND STANDARD

Model No : APAM 141

Type : ANAESTHESIA MACHINES

Catalogue :

Short Description

ANAESTHESIA MACHINE DIAMOND STANDARD SUPPLIED BY DESCO MEDICAL INDIA

Product Description

Anaesthesia Machine Diamond Standard Supplied by Desco Medical India
 
Specification :-
Main body is made of High-strength engineering plastic rack, light,beautiful and corrosion resistant
It can be applied on both Adult & Child
Gas source is O2 & N2O: 0.28~0.6MPa
Flow meter of O2 is 0.05~1.0L/min    1.1~10L/min
                        N2O: 0.05~1.0L/min   1.1~10L/min
Flow rate of rapid oxygen supply  25~75L/min
Low oxygen pressure alarm There will be sound alarm when the oxygen pressure< 0.2MPa 
Vaporizer Among Halothane, Enflurane, Isoflurane and Sevoflurane,any one can be chosen for application as required by the customer. The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate.
Reliable pneumatic transmission system.
Modularized design and upgrading is available.
Vaporizer has the function of automatic compensation based on pressure,temperature,and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Respiratory circuit         
working mode: all-close, semi-close, semi-open APL:≤12.5kPa
Respiratory bellows for adults, bellows for children are supplied with the Machine
Tidal volume range is 0~1500 ml
Ventilator Specs : Display mode High-definition 5.7” LCD screen display
Ventilation  modeI PPV,SIPPV, SIMV, MANUAL
Ventilation parameters Tidal volume 50~1500ml
Rate   2~99bpm
SIMV  2~20bpm
I:E      2:1~1:8
Inspiratory trigger pressure -10~20cmH2O
PEEP2~20cmH2O
Pressure limitation10~60cmH2O
SIGH 1.5 times the inspiratory time/100bpm
Parameters for ventilation monitoring tidal volume, minute ventilation volume, IPPV rate, SIMV rate,total respiratory rate, I/E, peak pressure of airway,pressure - time waveform, flow - time waveform, PEEP,  inspiratory trigger pressure,(average pressure, oxygen concentration, battery capacity)
Security Alarm System
Oxygen concentration alarm : upper limit setting range (21%~99%)
                                                low limit setting range    (18%~80%)
Airway pressure alarm upper limit setting range  5~60 cmH2O
Low limit setting range    0~50 cmH2O
Minute ventilation volume alarm  upper limit setting range  1~20 L/min
Low limit setting range    0~19L/min
Tidal volume : upper limit setting range  100~1500ml
                       low limit setting range0~1400ml
Sustained high-pressure alarm, it will give alarm when stress have consistently been higher than 2.5cmH2O
(Suffocation alarm, Power alarm, Intubation off alarm, battery voltage alarm)
Power  is AC 220V 50Hz